535 | SIEMENS - CONTROLS diversitech.com | 800.995.2222 ©2022 DiversiTech Corporation. All Rights Reserved Screw terminals Adjustable hys- teresis Undervoltage detection Overvoltage detection Stabilization time adjustable stDEL Tripping delay time adjustable Del Version of auxilia- ry contacts Measurable line voltage1 Item ID s s CO contact V Monitoring of phase sequence Auto RESET 3UG4511-1AN20 — — — — — 1 160 … 260 AC 3UG4511-1BN20 — — — — — 2 3UG4511-1AP20 — — — — — 1 320 … 500 AC 3UG4511-1BP20 — — — — — 2 3UG4511-1AQ20 — — — — — 1 420 … 690 AC 3UG4511-1BQ20 — — — — — 2 Monitoring of phase sequence, phase failure and phase unbalance Auto RESET, closed-circuit principle, unbalance threshold permanently 10% 3UG4512-1AR20 — — — — — 1 160 … 260 AC 3UG4512-1BR20 — — — — — 2 Monitoring of phase sequence, phase failure, unbalance and undervoltage Analogically adjustable, Auto RESET, closed-circuit principle, asymmetry and undervoltage threshold permanently 20% 3UG4513-1BR20 5% of set value √ — — 0.1 … 20 2 160 … 690 AC Digitally adjustable, Auto RESET or Manual RESET, open-circuit or closed-circuit principle, asymmetry threshold 0 or 5 ... 20% 3UG4614-1BR20 Adjustable 1 ... 20 V √ — 0.1 … 20 0.1 … 20 2 160 … 690 AC Monitoring of phase sequence, phase failure, overvoltage and undervoltage Digitally adjustable, Auto RESET or Manual RESET, open-circuit or closed-circuit principle 3UG4615-1CR20 Adjustable 1 ... 20 V √ √ — 0.1 … 202 22 160 … 690 AC Monitoring of phase sequence, phase and N conductor failure, overvoltage and undervoltage Digitally adjustable, Auto RESET or Manual RESET, open-circuit or closed-circuit principle adjustable 3UG4616-1CR20 Adjustable 1 ... 20 V √ √ — 0.1 … 202 22 90… 400 AC against N Automatic correction of the direction of rotation in case of wrong phase sequence, phase failure, unbalance, overvoltage and undervolt- age Digitally adjustable, Auto RESET or Manual RESET, open-circuit or closed-circuit principle, asymmetry threshold 0 or 5 ... 20% 3UG4617-1CR20 Adjustable 1 ... 20 V √ √ — 0.1 … 202 23 160 … 690 AC Automatic correction of the direction of rotation in case of wrong phase sequence, phase and N conductor failure, phase unbalance, overvoltage and undervoltage Digitally adjustable, Auto RESET or Manual RESET, open-circuit or closed-circuit principle, threshold 0 or 5 ... 20% 3UG4618-1CR20 Adjustable 1 ... 20 V √ √ — 0.1 … 202 23 90… 400 AC against N Function Relays, Interfaces and Converters 3UG45, 3UG46 Monitoring Relays for Stand-Alone Installation Line monitoring √ Function available — Function not available 1) Absolute limit values. 2) 1 CO contact each and one tripping delay time each for Umin and Umax. 3) 1 CO contact each for power system fault and phase sequence correction. TIMING | MONITORING | RELAYS
DiversiTech_Packard_2022_Catalog
| Title Name |
Pages |
Delete |
Url |
| Empty |
Ai generated response may be inaccurate.
Search Text Block
Page #page_num
#doc_title
Hi $receivername|$receiveremail,
$sendername|$senderemail wrote these comments for you:
$message
$sendername|$senderemail would like for you to view the following digital edition.
Please click on the page below to be directed to the digital edition:
$thumbnail$pagenum
$link$pagenum
Your form submission was a success.
Downloading PDF
Generating your PDF, please wait...
This process might take longer please wait